首页 | 本学科首页   官方微博 | 高级检索  
     检索      

仅用一根局部微结构长周期光纤光栅实现温度与弯曲曲率的同时测量
引用本文:曹晔,裴庸惟,童峥嵘.仅用一根局部微结构长周期光纤光栅实现温度与弯曲曲率的同时测量[J].物理学报,2014,63(2):24206-024206.
作者姓名:曹晔  裴庸惟  童峥嵘
作者单位:天津理工大学计算机与通信工程学院, 薄膜电子与通信器件重点实验室, 天津 300384
基金项目:国家自然科学基金(批准号:61107052)和天津市高等学校科技发展基金(批准号:2012)资助的课题.
摘    要:提出并制作了一种具有微结构缺陷的局部微结构长周期光纤光栅,该光栅是用氢氟酸局部腐蚀长周期光纤光栅,在包层区域形成局部缺陷得到的.理论分析与实际制作表明,局部腐蚀会改变包层模的有效折射率调制,相当于在缺陷部分引入一个相移,在其光谱图上表现为在透射阻带中打开一个透射窗口,形成两个透射阻带和一个透射通带.在此基础上对其进行了传感实验,研究了两个透射阻带和透射通带的温度和弯曲特性.实验结果表明:透射通带和两透射阻带的温度灵敏度相同,均约为0.05 nm/?C;而透射通带的弯曲曲率灵敏度(约为-2.61 nm/m-1)小于透射阻带的弯曲曲率灵敏度(约为-4.71 nm/m-1),因此利用敏感矩阵,可以仅用一根光栅对弯曲曲率和温度双参量进行同时测量.

关 键 词:局部微结构长周期光纤光栅  温度  弯曲  双参量测量
收稿时间:2013-10-21

Simultaneous measurement of temperature and bending-curvature using a single local micro-structured longperiod fiber grating
Cao Ye,Pei Yong-Wei,Tong Zheng-Rong.Simultaneous measurement of temperature and bending-curvature using a single local micro-structured longperiod fiber grating[J].Acta Physica Sinica,2014,63(2):24206-024206.
Authors:Cao Ye  Pei Yong-Wei  Tong Zheng-Rong
Institution:Key Laboratory of Film Electronics and Communication Devices, School of Computer and Communication Engineering, Tianjin University of Technology, Tianjin 300384, China
Abstract:A local micro-structured long-period fiber grating (LMSLPFG) is proposed and investigated experimentally. The LMSLPFG is fabricated by using hydrofluoric acid (HF) to partially etch a standard long-period fiber grating (LPFG), thereby forming a local defect in the cladding. The theoretical analysis and experimental results show that partially etching will change the effective refractive index modulation in the cladding mode, which equivalently introduces a phase shift into the part of defect and manifests, in the spectrogram, as openning a transmission window between the stopbands, forming two transmission stopbands and one transmission passband. On this basis we study the temperatures and bending characteristics of the two stopbands and one passband. The results show that the temperature sensitivities of the two stopbands and one passband are all approximately 0.05 nm/℃; the bending sensitivity of the passband (2.61 nm/m-1) is less than those of two stopbands (4.71 nm/m-1). Thus by using the sensitive matrix, we can simultaneously measure the curvature and temperature, with only one grating used.
Keywords:LMSLPFG  temperature  curvature  double-parameter-measurement
本文献已被 CNKI 等数据库收录!
点击此处可从《物理学报》浏览原始摘要信息
点击此处可从《物理学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号