首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Influence of scanning velocity on bovine shank bone ablation with pulsed CO2 laser
Authors:Xianzeng Zhang  Shusen Xie  Qing Ye  Zhenlin Zhan
Institution:[1]Institute of Laser and Optoelectronics Technology, Fujian Provincial Key Laboratory for Photonics Techonology, Key Laboratory of Opto-Electronic Science and Technology for Medicine of Ministry of Education, Fujian Normal University, Fuzhou 350007 [2]Department of Otolaryngology, Fujian Provincial Hospital, Fuzhou 350001 [3]provincial Clinical College of Fujian Medical University, Fuzhou 350001
Abstract:The influence of scanning speed on hard bone tissue ablation is studied with a 10.6-μm laser. The groove morphology and the thermal damage created in bovine shank bone by pulsed CO2 laser are examined as a function of incident fluence by optical microscope following standard histological processing. The results show that ablation groove width, depth and ablation volume, as well as the zone of thermal injury, increase gradually with incident fluence. As compared to the result for high scanning speed, the lower scanning speed always produces larger ablation volume but thicker zone of thermal injury. It is evident that scanning speed plays an important role in the ablation process. In clinical applications, it is important to select appropriate scanning speed to obtain both high ablation rates and minimal thermal injury.
Keywords:
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏