首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Pitch strength decreases as F0 and harmonic resolution increase in complex tones composed exclusively of high harmonics
Authors:Ives D Timothy  Patterson Roy D
Institution:Centre for Neural Basis of Hearing, Department of Physiology, Development and Neuroscience, University of Cambridge, Downing Street, Cambridge, CB2 3EG, United Kingdom. dti20@cam.ac.uk
Abstract:A melodic pitch experiment was performed to demonstrate the importance of time-interval resolution for pitch strength. The experiments show that notes with a low fundamental (75 Hz) and relatively few resolved harmonics support better performance than comparable notes with a higher fundamental (300 Hz) and more resolved harmonics. Two four note melodies were presented to listeners and one note in the second melody was changed by one or two semitones. Listeners were required to identify the note that changed. There were three orthogonal stimulus dimensions: F0 (75 and 300 Hz); lowest frequency component (3, 7, 11, or 15); and number of harmonics (4 or 8). Performance decreased as the frequency of the lowest component increased for both F0's, but performance was better for the lower F0. The spectral and temporal information in the stimuli were compared using a time-domain model of auditory perception. It is argued that the distribution of time intervals in the auditory nerve can explain the decrease in performance as F0, and spectral resolution increase. Excitation patterns based on the same time-interval information do not contain sufficient resolution to explain listener's performance on the melody task.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏