Numerical study on electrostatic potential distribution of large cylindrical oil tanks
Institution:1. Department of General and Inorganic Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, Pardubice 532 10, Czech Republic;2. Department of Inorganic Technology, Faculty of Chemical Technology, University of Pardubice, Doubravice 41, Pardubice 532 10, Czech Republic;3. Joint Laboratory of Solid State Chemistry of Institute of Macromolecular Chemistry of the Academy of Sciences of the Czech Republic and University of Pardubice, Faculty of Chemical Technology, Studentská 95, Pardubice 532 10, Czech Republic
Abstract:This study carried out a numerical simulation of electrostatic potential distribution in the cylindrical oil tank, focusing on spatial distribution of electrostatic potential and the variation tendency of the potential in the filling operation. Electrostatic potential distribution of stationary oil was illustrated, and the relationship between the electrostatic potential distribution and some parameters of the tank and oil was analyzed as well. Dynamic electrostatic distribution was studied when charged oil is filling into the tank, and ESD prevention measures’ effects on electrostatic potential distribution were simulated. Finally, calculation results of two other types of oil tanks were presented in brief.
Keywords:Storage tank  Electrostatic distribution  Numerical study  ESD protections
本文献已被 ScienceDirect 等数据库收录!