首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Performance comparison of an 241Am-Be neutron source-based PGNAA setup with the KFUPM PGNAA setup
Authors:A A Naqvi  M M Nagadi
Institution:(1) Center for Applied Physical Sciences, King Fahd University of Petroleum and Minerals, P.O. Box 1815, Dhahran, 31261, Saudi Arabia
Abstract:Monte Carlo calculations have been carried out to compare the performance of an 241Am-Be neutron source-based prompt gamma neutron activation analysis (PGNAA) setup with that of the 2.8 MeV neutron-based PGNAA setup at King Fahd University of Petroleum and Minerals (KFUPM) to analyze Portland cement samples. This work is a part of a wide Monte Carlo studies being conducted at KFUPM in search of a more efficient neutron source for its 2.8 MeV neutrons, from the D(d,n) reaction, based PGNAA facility. In this study an 241Am-Be neutron source-based PGNAA setup was simulated. For comparison, the diameter of a cylindrical external moderator of the 241Am-Be neutron source, based PGNAA setup, was assumed to be similar to that used in the KFUPM PGNAA setup. The results of this study revealed that although the optimum geometry of the 241Am-Be neutron source-based setup is similar to that of the KFUPM PGNAA facility, the performance of the 241Am-Be neutron source-based setup is slightly poorer than that of the 2.8 MeV neutron-based setup. This revised version was published online in July 2006 with corrections to the Cover Date.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏