LOW POWER MEASUREMENTS ON THE NEW RF OUTPUT SYSTEM OF A 170 GHZ, 2 MW COAXIAL CAVITY GYROTRON |
| |
Authors: | T Rzesnicki J Jin B Piosczyk M Thumm G Michel and D Wagner |
| |
Institution: | (1) Forschungszentrum Karlsruhe GmbH, Institut für Hochleistungsimpulsund Mikrowellentechnik, P.O. Box 3640, D-76021 Karlsruhe, Germany;(2) Universit?t Karlsruhe, Institut für H?chstfrequenz und Elektronik, 76128 Karlsruhe, Germany;(3) Max-Planck-Institut für Plasmaphysik, 17491 Greifswald, Germany;(4) Max-Planck-Institut für Plasmaphysik, 85740 Garching, Germany |
| |
Abstract: | The design of the quasi optical (q. o.) RF output system for the first industrial prototype of the European 170 GHz, 2 MW,
CW coaxial cavity gyrotron for electron cyclotron heating and current drive in ITER has been verified at a low power level.
Results of measurements with a high quality TE34,19-mode generator are in good agreement with the design calculations. This strengthens the confidence both to the employed design
codes and to the manufacturing quality of the launcher and mirrors. |
| |
Keywords: | Coaxial Cavity Gyrotron RF Output System Quasi Optical Converter Low Power Measurements Electron Cyclotron Heating |
本文献已被 SpringerLink 等数据库收录! |
|