Determination of acetazolamide in human urine samples by reversed-phase high-performance liquid chromatography in the presence of xanthines.
Authors:R Herráez-Hernández  P Campíns-Falcó  A Sevillano-Cabeza
Affiliation:Departamento de Química Analítica, Facultad de Química, Universidad de Valencia, Burjassot, Spain.
Abstract:
A simple, rapid and selective high-performance liquid chromatographic assay for the determination of acetazolamide in urine samples is described. After extraction with ethyl acetate, the drug is chromatographed on an HP-Hypersil ODS-C18 column with a mobile phase of acetonitrile-phosphate buffer (pH 3) and ultraviolet detection at 275 nm. The efficiency of the extraction, the linearity and the reproducibility of the method permit the evaluation of acetazolamide urinary excretion a long time after its administration.