首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Quality control of201TlCl solution obtained at IPEN-CNEN/SP
Authors:L Fernandes  C Pagano Gonçalves da Silva
Institution:(1) IPEN-CNEN/SP, Instituto de Pesquisas Energéticas e Nucleares-Comissão Nacional de Energia Nuclear, Pinheiros, P.O.Box 11049, CEP:05499 São Paulo, Brazil
Abstract:The radiopharmaceutical201TlCl(thallium-201 chloride) is used in nuclear medicine for myocardial visualization. The solution of201TlCl was prepared using201Tl obtained by irradiating a natural mercury target with protons from the CV-28 cyclotron installed at IPEN-CNEN/SP. This solution was subjected to different quality control processes required for its use in medicine. Some of these controls concerned the determination of the radionuclidic impurities:200Tl,202Tl and203Hg; the chemical identification of201Tl+; the hydrazine concentration, mercury contamination and the presence of phosphate. Furthermore. the biological distribution ldquoin Wistarrdquo rats and tests for sterility, pyrogenicity and toxicity were carried out. It was verified that the solution obtained was in the form of thallous chloride. This radiopharmaceutical gave good heart images in animals but due to the high levels of200Tl and202Tl its use in humans is not possible unless enriched202Hg is used as target in the irradiation.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号