A new oxidimetric reagent: potassium dichromate in a strong phosphoric acid medium--VII. Photometric titration of vanadium(IV) and of cerium(III) alone and in mixtures with iroN(II)
Authors:Rao G G  Rao P K
Institution:Department of Chemistry, Andhra University, Waltair, India.
Abstract:Vanadium(IV) can be accurately titrated with potassium dichromate in media containing phosphoric acid of 3-12M concentration: the change in absorption of vanadium(IV) is followed in the region 660 mmicro using a red filter. It is more convenient to carry out the titration in 3M phosphoric acid because at higher concentrations chloride, nitrate, cerium(III) and manganese(II) may interfere. Photoelcetric titration is more convenient than potentiometric because the former can be made in a 3M phosphoric acid medium, whereas the latter is possible only in 12M phosphoric acid. The simultaneous differential photometric titration of iron(II) and vanadium(IV) is also possible. Conditions have been found for the photometric titration of cerium(III) and of cerium(III) plus iron(II). The titration is carried out (at 450 mmicro or with a blue filter) in about 10.5M phosphoric acid. Application of the method to a cerium mineral is considered.
Keywords:
本文献已被 PubMed 等数据库收录!