A splitless Curie point pyrolysis capillary inlet system for use with the adsorption wire technique of vapour analysis
Authors:J. D. Twibell  J. M. Home  K. W. Smalldon
Affiliation:(1) Home Office Central Research Establishment, Aldermaston, RG7 4PN Reading, Berkshire, UK;(2) Present address: Home Office Forensic Science Laboratory, Washington Hall, Euxton, PR7 6HJ Chorley, Lanes, UK
Abstract:
Summary A splitless Curie point pyrolysis inlet system for capillary columns has been built using conventional packed column apparatus. This has enabled the adsorption wire analysis system, for the rapid collection and direct GC analysis of vapours, to be used with capillary columns. Use of the technique for detecting traces of hydrocarbon fuels in arson investigation is described, as are problems occurring in its use.
Keywords:Arson  Curie point pyrolysis  Air pollution  Vapour sampling  Capillary PC