Evaluation of probe lasers employed in optical diagnostics for phase transformation of thin films during excimer laser crystallization
Authors:Chil-Chyuan Kuo  
Institution:

aDepartment of Mechanical Engineering, Mingchi University of Technology, No. 84, Gungjuan Road, Taishan Taipei Hsien 243, Taiwan

Abstract:The stability and reliability of probe laser is an important factor affecting the inspection of the phase transformation process of Si thin films during excimer laser crystallization using in-situ time-resolved optical measurements. The changes in 2D intensity profile, peak power density, and beam wander of the commonly used helium–neon (He–Ne) and diode laser are investigated experimentally. It is found that the peak power density of He–Ne laser is higher than that of diode laser, while the total power of He–Ne laser is lower than that of diode laser. Although the instability in the peak power density of He–Ne laser will increase with increasing the operation time, the beam stability of He–Ne laser is better than that of diode laser. For long-time operation (>24 h) of optical measurements, the diode laser is a good candidate of probe laser. Conversely, the diode laser is suitable for the short-time operation (<24 h) of optical measurements because the beam-wander is higher than that of He–Ne laser.
Keywords:Probe lasers  Optical diagnostics  Thin films  Excimer laser crystallization
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号