首页 | 本学科首页   官方微博 | 高级检索  
     

ICP-AES法测定方铅矿中多元素的方法研究
引用本文:王松君,常平,王璞珺,侯天平,侯悦. ICP-AES法测定方铅矿中多元素的方法研究[J]. 分析试验室, 2007, 26(3): 39-42
作者姓名:王松君  常平  王璞珺  侯天平  侯悦
作者单位:苏州科技学院基础实验教学中心,苏州,215009;吉林大学地球科学学院,长春,130061;吉林大学地球勘探与科学学院,长春,130026;吉林大学地球科学学院,长春,130061;吉林工程技术师范学院信息工程学院,长春,130052;浙江大学材料化工学院,杭州,310027
摘    要:
采用电感耦合等离子体原子发射光谱法(ICP-AES)进行方铅矿中多元素同时测定.通过对方铅矿样品化学处理试验建立了HCl-NH4Cl-HNO3的溶矿体系.本体系采用基体匹配、背景系数和元素干扰系数校正及元素内标法确定了最佳综合实验测试条件.本实验建立的ICP-AES法同时测定方铅矿中镉、钴、铜、铁、铟、铅、锌7种元素的方法,本方法测量相对误差RE (n=8)为1.50%~7.50%,相对标准偏差RSD (n=8)为1.7%~5.7%.经国家一级标准物质GBW 07269分析验证可以满足方铅矿单矿物样品的分析要求.

关 键 词:方铅矿  元素干扰  基体匹配
文章编号:1000-0720(2007)03-039-04
修稿时间:2006-05-012006-08-26

Study on determination of multi elements in galena by inductively coupled plasma atomic emission spectrometry
WANG Song-jun,CHANG Ping,WANG Pu-jun,HOU Tian-ping,HOU Yue. Study on determination of multi elements in galena by inductively coupled plasma atomic emission spectrometry[J]. Chinese Journal of Analysis Laboratory, 2007, 26(3): 39-42
Authors:WANG Song-jun  CHANG Ping  WANG Pu-jun  HOU Tian-ping  HOU Yue
Affiliation:1. Center of Basic Experiment University of Science and Technology of Suzhou, Suzhou 215009; 2. College of Earth Science, JiLin University, Changchun 130061; 3. College of GeoExploration Science and Technology, JiLin University, Changchun 130026; 4. College of information engineering, Jilin Teachers Institute of Engineeing and Technology, Changchun 130052; 5. College of Material and Chemical Engineering, Zhejiang University, Hongzhou 310027
Abstract:
A method for simultaneous determination of multi elements in galena by inductively coupled plasma atomic emission spectrometry(ICP-AES) was studied.The system of HCl-NH4Cl-HNO3 dissolving ore was set up by chemical treatment for galena samples.The optimal experimental conditions were obtained by matrix element match,background coefficient and element interference coefficient correction as well as element internal standard method.The method of simultaneous determination of seven elements in galena such as cadmium,cobalt,copper,iron,indium, lead and zinc by inductively coupled plasma atomic emission spectrometry was established.The relative errors RE(n=8) are between 1.5% and 7.5%,and relative standard deviations RSD(n=8) are between 1.7% and 5.7%.The method can satisfy demand for galena analysis of single mineral sample through analysis verification for national first level standard material(GBW 07269).
Keywords:Galena   Element interference   Matrix matching