首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Spectrophotometric determination of thiosulfate and tetraphenylborate ions through ligand exchange reaction at solid surface
Authors:M C Mehra  P O'Brien
Institution:(1) Chemistry Department, Université de Moncton, E1A 3E9 Moncton, N. B., Canada;(2) Present address: department of Excise and Customs, Ottawa, Ontario
Abstract:Summary A Spectrophotometric method is presented for the microanalysis of analytically important thiosulfate and tetraphenylborate anions in an aqueous solution. The method is based on ligand exchange in a dynamic approach incorporating a solid reagent mercuric chloranilate. The common cations Na+, K+, Al3+, Ca2+, and Mg2+ do not interfere and the anions CH3COO, C2O4 2–, SO4 , C3H4OH-(COO)3 3– and NO3 do not cause any adverse effects. The heavy metals Pb2+, Cd2+, Fe2+, Cu2+, and Zn2+ cause a negative interference while the halogens and SCN type of anions give a positive interference. The method is sensitive up to 5 ppm of tetraphenyl-borate anion and 10 ppm of the thiosulfate anion.
Zusammenfassung Ein spektrophotometrisches Mikroverfahren zur Bestimmung von Thiosulfat und Tetraphenylborat in wäßriger Lösung wurde angegeben. Es beruht auf dem Ligandenaustausch mit Hilfe von Quecksilberchloranilat. Die üblichen Kationen Na, K, Al, Ca und Mg stören nicht; auch die Anionen Acetat, Oxalat, Sulfat, Zitrat und Nitrat haben keinen störenden Einfluß. Die Schwermetalle Pb(II), Cd, Fe(II), Cu(II) und Zn verursachen negative Fehler, die Halogene, Thiocyanat und dgl. haben positive Fehler zur Folge. Die Methode ist empfindlich bis zu 5 ppm Tetraphenylborat und 10 ppm Thiosulfat.
Keywords:
本文献已被 SpringerLink 等数据库收录!