首页 | 本学科首页   官方微博 | 高级检索  
     


High-sensitivity determination of lead and cadmium based on the Nafion-graphene composite film
Authors:Jing Li  Shaojun Guo  Yueming Zhai  Erkang Wang
Affiliation:a State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin, 130022, China
b Graduate School of the Chinese Academy of Sciences, Beijing, 100039, China
Abstract:Graphene nanosheets, dispersed in Nafion (Nafion-G) solution, were used in combination with in situ plated bismuth film electrode for fabricating the enhanced electrochemical sensing platform to determine the lead (Pb2+) and cadmium (Cd2+) by differential pulse anodic stripping voltammetry (DPASV). The electrochemical properties of the composite film modified glassy carbon electrode were investigated. It is found that the prepared Nafion-G composite film not only exhibited improved sensitivity for the metal ion detections, but also alleviated the interferences due to the synergistic effect of graphene nanosheets and Nafion. The linear calibration curves ranged from 0.5 μg L−1 to 50 μg L−1 for Pb2+ and 1.5 μg L−1 to 30 μg L−1 for Cd2+, respectively. The detection limits (S/N = 3) were estimated to be around 0.02 μg L−1 for Pb2+ and Cd2+. The practical application of the proposed method was verified in the water sample determination.
Keywords:Nafion-graphene   Nanosheets   Lead   Cadmium   Bismuth
本文献已被 ScienceDirect 等数据库收录!