首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Evaluation of a carbon paste electrode modified with organofunctionalized amorphous silica in the cadmium determination in a differential pulse anodic stripping voltammetric procedure
Authors:Marino Glimaldo  Bergamini Márcio F  Teixeira Marcos F S  Cavalheiro Eder T G
Institution:Departamento de Quimica, Universidade Federal de S?o Carlos, S?o Carlos, SP, Brazil.
Abstract:The determination of cadmium using a carbon paste electrode modified with organofunctionalized amorphous silica with 2-benzothiazolethiol was investigated. The Cd(II) oxidation peak was observed around −0.80 V (vs. SCE) in phosphate buffer (pH 4.0) in differential pulse anodic stripping voltammetry. The best results were obtained under the following optimized conditions: 1 min accumulation time, 50 mV pulse amplitude, 20 mV s−1 scan rate in phosphate buffer pH 4.0. Using such parameters a linear dynamic range from 5.6×10−7 to 3.5×10−5 mol l−1 Cd(II) was observed with a sensitivity of 2.83 μA mol−1 l, limit of detection 1.0×10−7 mol l−1. Cd(II) spiked in a natural water sample was determined with 99% mean recovery at 10−7 mol l−1 level. Interference were also evaluated.
Keywords:Cadmium  Carbon paste electrode  Amorphous silica  2-Benzothiazolethiol  Differential pulse anodic stripping voltammetry
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏