首页 | 本学科首页   官方微博 | 高级检索  
     


Experimental study of the Raman strain rosette based on the carbon nanotube strain sensor
Authors:Wei Qiu  Yi‐Lan Kang  Zhen‐Kun Lei  Qing‐Hua Qin  Qiu Li  Quan Wang
Abstract:
This work presents a new technique named Raman strain rosette for the micro‐strain measurement of both Raman active and Raman inactive materials. The technique is based on the theoretical model of the carbon nanotube (CNT) strain sensor that applies the resonance and polarization Raman properties of CNTs and calculates the synthetic contributions of uniformly dispersed CNTs to the entire Raman spectrum. In our work, the proposed technique is applied in different experiments on the Raman inactive materials, such as step‐by‐step uniaxial tensile and Raman mapping around a circular hole. The experimental results reached by the Raman strain rosette are consistent with the actual values as a whole. This study verifies that the Raman strain rosette is applicable to quantitative measurement of all the in‐plane components of the strain tensor (including both normal and shear strains) by three polarized Raman detections for each sampling spot on a microscale. The technique is further applicable to achieving the strain fields through Raman mapping. Copyright © 2010 John Wiley & Sons, Ltd.
Keywords:Raman strain rosette  carbon nanotube strain sensor  Raman inactive  measurement of strain components  polarized Raman spectroscopy