Abstract:A grafted polymer reference electrode (GPRE) (polystyrene grafted with acrylonitrile as a monomer using gamma irradiation) was fabricated as a reference electrode using cyclic voltammetry (CV). The redox process of K3Fe(CN)6 during CV was studied. It was found that the redox current peaks of Fe(II)/Fe(III) in 0.1 M of KCl as supporting electrolyte is given the same oxidation–reduction current as in the Ag/AgCl reference electrode, indicating a good result of GPRE and, hence, it can be used for voltammetric analysis technique. The physical properties of GPRE include good hardness, insoluble in non-aqueous electrolytes (except dimethyl formamide and chloroform), and good stability at different solvents. In addition, the sensitivity under conditions of CV is significantly dependent on the scan rate (SR) and variation in concentration. At different SRs, redox peaks of K3Fe(CN)6 were observed in a reversible process: Fe(II)/Fe(III). Interestingly, the redox reaction of Fe(II)/Fe(III) solution using GCE versus GPRE remains constant even after 15 cyclings. It is therefore evident that the GPRE possesses some degree of stability. Also, the new reference electrode GPRE has improved the properties of electroanalysis of CV on the working electrode GCE in reliability with the relative standard deviation.