首页 | 本学科首页   官方微博 | 高级检索  
     


A novel approach in dispersive liquid-liquid microextraction based on the use of an auxiliary solvent for adjustment of density: UV-VIS spectrophotometric and graphite furnace atomic absorption spectrometric determination of gold based on ion pair formation
Authors:  via Kocú  rová  ,Jana &Scaron  krlí  ková  ,Vasil Andruch
Affiliation:a Department of Analytical Chemistry, University of P.J. Šafárik, SK-04154 Košice, Slovak Republic
b Department of Chemistry, College of Nyíregyháza, HU-4400 Nyiregyháza, Hungary
c Department of Inorganic and Analytical Chemistry, University of Debrecen, HU-4010 Debrecen, Hungary
Abstract:This paper presents a novel approach to dispersive liquid-liquid microextraction (DLLME), based on the use of an auxiliary solvent for the adjustment of density. The procedure utilises a solvent system consisting of a dispersive solvent, an extraction solvent and an auxiliary solvent, which allows for the use of solvents having a density lower than that of water as an extraction solvent while preserving simple phase separation by centrifugation. The suggested approach could be an alternative to procedures described in the literature in recent months and which have been devoted to solving the same problem. The efficiency of the suggested approach is demonstrated through the determination of gold based on the formation of the ion pair [Au(CN)2] anion with Astra Phloxine (R) reagent and its extraction using the DLLME procedure with subsequent UV-VIS spectrophotometric and graphite furnace atomic absorption spectrometric detection. The optimum conditions were found to be: pH 3; 0.8 mmol L−1 K4[Fe(CN)6]; 0.12 mmol L−1 R; dispersive solvent, methanol; extraction solvent, toluene; auxiliary solvent, tetrachloromethane. The calibration plots were linear in the ranges 0.39-4.7 mg L−1 and 0.5-39.4 μg L−1 for UV-VIS and GFAAS detection, respectively; thus enables the application of the developed method in two ranges differing from one from another by three orders of magnitude. The presented approach can be applied to the development of DLLME procedures for the determination of other compounds extractable by organic solvents with a density lower than that of water.
Keywords:Dispersive liquid-liquid microextraction   Auxiliary solvent   Ion pair   Gold   UV-VIS spectrophotometry   Graphite furnace atomic absorption spectrometry
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号