Radiometric efficiency of analytical filters at different physical conditions |
| |
Authors: | Khalaf Hyam Nazmy Bader Mostafa Mostafa Yuness Abdelfatah Zhukovsky Michael |
| |
Affiliation: | 1.Ural Federal University, Mira Street 19, Ekaterinburg, Russia, 620002 ;2.Institute of Industrial Ecology UB RAS, Sophy Kovalevskoy St. 20, Ekaterinburg, Russia, 620990 ;3.Physics Department – Faculty of Science, Minia University, Minia, Egypt ; |
| |
Abstract: | The radiometric efficiency of three analytical filters AFA-RSP-20, AFA-RMP-20 and AFA-RMV-20 was examined at different air velocities and aerosol number concentrations. An experimental setup had been constructed with 2 m3 radon chamber. Alpha radiometry was used to measure the deposited activities in the filters. Aerosols parameters like number concentration and size distribution are measured continuously with an aerosol diffusion spectrometer (ADS). RMV filter has a stable efficiency ~ 99.8%. The RSP and RMP filters efficiency is depending on the aerosol concentration and air sampling velocity. The effect of an aerosol concentration on the filter efficiency is more obvious than the effect of air velocity. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|