首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Design of a portable luminescence bio-tool for on-site analysis of heavy metals in water samples
Authors:Rupesh K Mishra  Amina Rhouati  Diana Bueno  Muhammad Waqas Anwar  Shakir Ahmad Shahid  Vinay Sharma
Institution:1. BAE: Biocapteurs-Analyses-Environnement, Université de Perpignan, Perpignan, France;2. Department of Biosciences and Biotechnology, Banasthali University, Rajasthan, India;3. Department of Nano-Engineering, University of California, San Diego, CA, USA;4. Ecole Nationale Supérieure de Biotechnologie, Constantine, Algérie;5. Bioelectronics Section, Department of Electrical Engineering, CINVESTAV-IPN, Mexico, Mexico;6. Department of Computer Science, COMSATS Institute of Information technology, Lahore, Pakistan;7. Department of Chemistry, University of Sargodha, Sargodha, Pakistan;8. Amity University Rajasthan, Jaipur, India
Abstract:ABSTRACT

In this work, we report an innovative tool for heavy metal screening in water samples. This new chemiluminescent set-up screens the light generated from luminol oxidation by horseradish peroxidase (HRP) in the presence of hydrogen peroxide (H2O2). The pollutant concentrations in real water samples were calculated by studying the effect of metal ions on chemiluminescence signal. Owing to its simplicity, portability and low cost, this approach presents a real alternative to classical optical methods. It is constructed with simple materials: a black box containing a cuvette and a micro-camera. When the enzymatic reaction takes place, the luminescence is captured by the camera placed in upright position. The image can be saved automatically in a computer for further analysis using a MATLAB interface. The RGB diagram is then established to determine the analyte concentrations in the tested samples. This method was successfully applied for the determination of mercury (Hg), lead (Pb) and cadmium (Cd) in lake and field water samples. In these experiments, three concentrations of each analytes were tested (5, 25 and 50 µg/L). We noted a good proportionality between the analyte concentration and the chemiluminescent detection intensity. Detection of binary and tertiary combinations of heavy metals has been also investigated. The developed biosensor showed low detection limits for the tested heavy metals: 1, 0.7 and 0.02 for Hg2+, Pb2+ and Cd2+, respectively. Finally, excellent recoveries ranging from 98% to 104% were obtained for the HRP-inhibition assay.
Keywords:Portable device  on-site analysis  heavy metals  luminescence assay  water samples
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号