Flow injection chemiluminescence determination of paracetamol
Authors:Ruengsitagoon Wirat  Liawruangrath Saisunee  Townshend Alan
Institution:a Department of Pharmaceutical Chemistry, Faculty of Pharmaceutical Sciences, Khon Kaen University, Khon Kaen 40002, Thailand
b Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand
c Department of Chemistry, The University of Hull, Hull HU6 7RX, UK
Abstract:A simple chemiluminometric method using flow injection has been developed for the determination of paracetamol (acetaminophen), based on the chemiluminescence produced by the reduction of tris(2,2′-bipyridyl)ruthenium(III). The latter is obtained by oxidation of tris(2,2′-bipyridyl)ruthenium(II) by potassium permanganate in dilute sulphuric acid in the presence of paracetamol. A standard or sample solution was injected into the ruthenium(II) stream (flow rate 1.5 ml min−1) which was then merged with potassium permanganate in dilute sulphuric acid stream (flow rate 0.5 ml min−1). The chemiluminescence intensity is enhanced by the presence of manganese(II) ions. Under the optimum conditions, a linear calibration graph was obtained over the range of 0.3-50.0 μg ml−1 and the detection limit was 0.2 μg ml−1 (s/n = 3). The relative standard deviation of the proposed method calculated from 20 replicate injections of 5.0 μg ml−1 paracetamol was 1.1%. The sample throughput was 90 h−1. The method was successfully applied to the determination of paracetamol in commercial pharmaceutical formulations.
Keywords:Chemiluminescence  Paracetamol  Flow injection  Ruthenium(II)
本文献已被 ScienceDirect PubMed 等数据库收录!