Degradation of m-xylene solution using ultrasonic irradiation
Authors:Xie Weiping  Qin Yan  Liang Dingmin  Song Dan  He Dewen
Institution:College of Construction and Environment Engineering, Shenzhen Polytechnic, Shenzhen, Guangdong Province, China. xiewp@szpt.edu.cn
Abstract:This study is to apply ultrasound to remove m-xylene, a volatile compound from aqueous solutions which causes environmental damage. High frequency ultrasound was used to investigate the effect of different operational parameters, such as m-xylene initial concentration, ultrasonic frequency and ultrasonic power. The degradation rate of m-xylene was increased with decreasing initial concentration of m-xylene and increasing frequency and power. Optimal conditions include 26.07 mg/L, 806.3 kHz and 70±1 W, in which MnO(2), Cu(2+), Fe(2+), and H(2)O(2) had little or no effect on the degradation. Moreover, the effect of radical scavengers such as Na(2)CO(3) and t-butyl was not obvious, which indicates that direct pyrolysis inside the collapsing bubbles has an important role in m-xylene ultrasonic removal. In addition, the degradation of m-xylene was observed to behave under pseudo-first-order kinetics with different experimental conditions tested in the present work.
Keywords:
本文献已被 PubMed 等数据库收录!