Pipette vial dispersive liquid–liquid microextraction combined with high‐performance liquid chromatography for the determination of benzoylurea insecticide in fruit juice
Authors:Xuefei Xi  Miyi Yang  Ganni Shen  Xiaoling Wu  Runhua Lu  Wenfeng Zhou  Sanbing Zhang  Haixiang Gao
Institution:Department of Applied Chemistry, China Agricultural University, Haidian District, Beijing, China
Abstract:A simple, sensitive, and efficient method of using a pipette vial to perform dispersive liquid–liquid microextraction based on the solidification of floating organic droplets was coupled with high‐performance liquid chromatography (HPLC) and a diode array detector for the preconcentration and analysis of four benzoylurea insecticides in fruit juice. In this method, 1‐dodecanol was used as an extractant, and a snipped pipette was used as an experimental vial to simplify the procedure of collecting and separating solidified extractant. The experimental parameters were optimized using a Plackett–Burman design and one‐factor‐at‐a‐time method. Under the optimal conditions in the water model, the limits of detection for analytes varied from 0.03 to 0.28 μg/L, and the enrichment factors ranged from 147 to 206. Linearity was achieved for diflubenzuron and flufenoxuron in a range of 0.5–500 μg/L, for hexaflumuron in a range of 1–500 μg/L, and for triflumuron in a range of 5–500 μg/L. The correlation coefficients for the analytes ranged from 0.9986 to 0.9994 with recoveries of 91.4–110.9%. Finally, the developed technique was successfully applied to fruit juice samples with acceptable results. The relative standard deviations of the analytes at two spiking levels (50 and 200 μg/L) varied between 0.2 and 4.5%.
Keywords:1‐Dodecanol  Benzoylurea insecticides  Floating organic droplet  High‐performance liquid chromatography  Microextraction
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号