首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Eco‐friendly ionic liquid assisted capillary electrophoresis and α‐acid glycoprotein‐assisted liquid chromatography for simultaneous determination of anticancer drugs in human fluids
Authors:Deia Abd El‐Hady  Hassan M Albishri  Rajesh Rengarajan
Institution:1. Chemistry Department, Faculty of Science‐North Jeddah, King Abdulaziz University, Saudi Arabia;2. Chemistry Department, Faculty of Science, Assiut University, Assiut, Egypt;3. Chemistry Department, Faculty of Science, King Abdulaziz University, Jeddah, Saudi Arabia
Abstract:In the current work, two eco‐friendly analytical methods based on capillary electrophoresis (CE) and reversed phase liquid chromatography (RPLC) were developed for simultaneous determination of the most commonly used anticancer drugs for Hodgkin's disease: methotrexate (MTX), vinblastine, chlorambucil and dacarbazine. A background electrolyte (BGE) of 12.5 mmol/L phosphate buffer at pH 7.4 and 0.1 µmol/L 1‐butyl‐3‐methyl imidazolium bromide (BMImBr) ionic liquid (IL) was used for CE measurements at 250 nm detection wavelength, 20 kV applied voltage and 25 °C. The rinsing protocol was significantly improved to reduce the adsorption of IL on the interior surface of capillary. Moreover, RPLC method was developed on α‐1‐acid glycoprotein (AGP) column. Mobile phase was 10 mmol/L phosphate buffer at pH 6.0 (100% v/v) and flow rate at 0.1 mL/min. As AGP is a chiral column, it was successfully separated l ‐MTX from its enantiomer impurity d ‐MTX. Good linearity of quantitative analysis was achieved with coefficients of determinations (r2) >0.995. The stability of drugs measurements was investigated with adequate recoveries up to 24 h storage time under ambient temperature. The limits of detection were <50 and 90 ng/mL by CE and RPLC, respectively. The using of short‐chain IL as an additive in BGE achieved 600‐fold sensitivity enhancement compared with conventional Capillary Zone Electrophoresis (CZE). Therefore, for the first time, the proposed methods were successfully applied to determine simultaneously the analytes in human plasma and urine samples at clinically relevant concentrations with fast and simple pretreatments. Developed IL‐assisted CE and RPLC methods were also applied to measure MTX levels in patients’ samples over time. Copyright © 2014 John Wiley & Sons, Ltd.
Keywords:AGP  anticancer drugs  CE  ionic liquids  biological fluids
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号