首页 | 本学科首页   官方微博 | 高级检索  
     检索      


High resolution molecular spectroscopy in the submillimeter region
Authors:M G Baldecchi  B Carli  M Carlotti  G Di Lonardo  F Forni  F Mencaraglia and A Trombetti
Institution:(1) Instituto Ricerche Onde Elettromagnetiche del C.N.R., Via Panciatichi 64, 50127 Firenze, Italy;(2) Istituto di Chimica Fisica e Spettroscopia dell'Universita' di Bologna, Viale Risorgimento 4, 40136 Bologna, Italy;(3) Istituto di Spettroscopia Molecolare del C.N.R., Via Castagnoli 1, 40126, Bologna, Italy;(4) Istituo di Fisica Superiore, Via S. Marta 501, Firenze, Italy
Abstract:Fourier Transform laboratory measurements have been carried out, for the first time in the 8–85 cm–1 spectral region, with an unapodized resolution of 3.3. 10–3 cm–1 and a frequency accuracy of 2. 10–4 cm–1. Samples from spectra of several molecules namely: CO, O3, H2O2, NO, NO2, HNO3, SO2, H2S, HOCL, NOCL, HNCO, ND3 and AsH3 are presented to show both the quality of the measurements and the type of information supplied by high resolution spectroscopy in the submillimeter region.
Keywords:Molecular Spectroscopy  Rotational Spectra  Fourier Spectroscopy  High Resolution Spectroscopy
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏