ICP-AES法测定Pd/Al_2O_3中钯的干扰问题
引用本文:刘东艳,张园力.ICP-AES法测定Pd/Al_2O_3中钯的干扰问题[J].光谱实验室,2001(3).
作者姓名:刘东艳  张园力
作者单位:中国科学院山西煤炭化学研究所煤转化国家重点实验室!太原市桃园南路27号030001
摘    要:本文研究了用 ICP- AES法测定 Pd/Al2 O3催化剂中钯所存在的干扰问题。考察了基体及所用试剂对钯测定的影响 ,发现氧化铝基体、硫酸等对钯的测定均有负干扰 ,提出采用基体匹配法测定 Pd/Al2 O3中的钯含量。方法回收率在 96%以上 ,9次测定相对标准偏差小于 3%

关 键 词:  催化剂  ICP-AES  干扰

Interference in the Determination of Palladium in Pd/Al_2O_3 by ICP-|AES
LIU Dong,Yan,ZHANG Yuan,Li.Interference in the Determination of Palladium in Pd/Al_2O_3 by ICP-|AES[J].Chinese Journal of Spectroscopy Laboratory,2001(3).
Authors:LIU Dong  Yan  ZHANG Yuan  Li
Abstract:The interference of the determining palladium in catalysts supported on aluminum oxide by ICP\|AES was reported.The interference conditions of inorganic acid and carrier were discussed.Pd in Pd/Al\-2O\-3 was determined by matrix matching method in order to deduce the interference of H\-2SO\-4 and Al\-2O\-3 matrix.The recoveries are higher than 96%,and the relative standard deviation are lower than 3%( n =9).
Keywords:Palladium  Catalysts  ICP\|AES  Interference  