首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Efficiency assessment of wastewater treatment plant based on SPMD sampling
Authors:Vladimír Ko?í  Tomá? Ocelka  Martin Mlejnek  Roman Grabic
Institution:(1) Department of Environmental Chemistry, ICT, 166 28, Prague, Czech Republic;(2) National Health Institute, 702 00 Ostrava, Czech Republic
Abstract:The efficiency of treatment processes forboth municipal and industrial wastewater (treatment plant-Ostrava, Czech Republic) focused on persistent organic pollutants (POPs) was assessed. Semipermeable membrane devices (SPMDs) as a sampling system were applied. Exposed SPMDs were analyzed both for chemical contaminants of POPs and toxicity response. The chemical analyses of PAHs were made by HPLC-FLD, PCDD/Fs and PCBs were analysed by GC/MS/MS on GCQ or PolarisQ (Thermoquest). Ecotoxicity data on chlorococcal alga Desmodesmus subspicatus (Scenedesmus subspicatus) and luminescent bacteria Vibrio fischeri are presented here. All toxicity data as effective volume Vtox are expressed. The results show good treatment ability of the treatment plant and proved used system as an appropriate tool for efficiency assessment of treatment and/or decontamination processes.
Keywords:Sewage treatment process                      Persistent organic pollutants                      Bioluminescence inhibition                      Algal bioassay                      Vtox