Instrumental neutron activation analysis of mass fractions of toxic metals in plastic |
| |
Authors: | Kwangwon Park |
| |
Affiliation: | Division of Metrology for Quality Life, Korea Research Institute of Standards and Science, 1 Doryong-Dong, Yuseong-Gu, Daejeon 305-340, South Korea |
| |
Abstract: | ![]() It is very challenging to decompose a plastic product for the purpose of analysis of hazardous elements contained. To circumvent such technical problem, it is imperative that an analyst employ a nondestructive analytical method free of any pretreatments. The analytical results of the concentrations of toxic metals such as Cd and Cr in polypropylene for seven samples at two different levels were obtained using the instrumental neutron activation analysis. This work was intended ultimately to establish certified reference materials (CRMs) of these metals in the polypropylene, traceable to the SI. The uncertainties associated with the analytical procedures were estimated in accordance with the ISO guideline. The results were subsequently validated by a comparison with those for CRM-680 and −681 of the Bureau Communautaire de Reference (BCR), which demonstrated acceptable agreement within their uncertainty ranges. |
| |
Keywords: | Neutron activation analysis Hazardous element Certified reference material Polypropylene Uncertainty |
本文献已被 ScienceDirect 等数据库收录! |
|