An improved gas chromatographic assay for spectinomycin hydrochloride |
| |
Authors: | J. Hoebus Li Ming Yun J. Hoogmartens |
| |
Affiliation: | (1) Laboratorium voor Farmaceutische Chemie, Faculteit Farmaceutische Wetenschappen, Katholieke Universiteit Leuven, Van Evenstraat 4, 3000 Leuven, Belgium |
| |
Abstract: | Summary A gas chromatographic assay for spectinomycin hydrochloride is described. The method is based on that prescribed by the United States Pharmacopeia (USP XXII). The method involves silylation of spectinomycin hydrochloride; phenazone is used as an internal standard. Spectinomycin and phenazone have adequate stability under the prescribed conditions. The stationary phase is 3% OV-17 on Gaschrom Q 100–120 mesh. The selectivity of the proposed method is better than that of the GLC method described in the USP XXII. |
| |
Keywords: | Gas chromatography Spectinomycin Silylation |
本文献已被 SpringerLink 等数据库收录! |