摘    要:提出了一个三参数积分法拟合恒电量强极化数据以测定Tafel斜率的新方法.实验证明,恒电量瞬态扰动测量碳钢在酸溶液中的腐蚀,获得的Tafel斜率与消除了溶液电阻影响的Tafel外推结果有很好的一致性,说明恒电量法有效地消除了溶液电阻对该体系测量结果的影响,并且通过电化学和失重实验验证表明,这种快速测量可以获得准确的腐蚀速率.这种新的恒电量强极化积分算法相对微分法的优势体现在算法简捷和用于数值计算的数据具有较高的信噪比,因此能够提高测量精度.

关 键 词:恒电量  Tafel斜率  积分法  碳钢  硫酸溶液  
收稿时间:2004-06-25
修稿时间:2004年6月25日

Determination of Tafel Slopes from Coulostatically Induced Transients and Its Integral Alogrithm
ZHAO Yong-Tao,GUO Xing-Peng,ZHAO Guang-Yu,DONG Ze-Hua,CHEN Guang-Zhang.Determination of Tafel Slopes from Coulostatically Induced Transients and Its Integral Alogrithm[J].Acta Physico-Chimica Sinica,2005,21(1):93-97.
Authors:ZHAO Yong-Tao  GUO Xing-Peng  ZHAO Guang-Yu  DONG Ze-Hua  CHEN Guang-Zhang
Institution:State Key Laboratory for Marine Corrosion and Protection, Luoyang Ship Material Research Institute, Qingdao 266071; Department of Chemistry, Huazhong University of Science and Technology, Wuhan 430074
Abstract:The mathematical model of a three-parameter method, based on an integral formulation, for analyzing the coulostatically induced transients is developed. This method can compute the Tafel slopes ba or bc and corrosion current density ic. The validity of the method is confirmed by the observation that the values of Tafel slope measured by coulostatic method are coincident with those obtained by Tafel lines extrapolation method with eliminating influence of IR drop, and the comparison of results obtained by solution analysis and electrochemical measurements shows that the method provides a faithful representation of corrosion behavior. The integral method has the advantages over differential method due to its simplicity and higher signal/noise ratio, so that the numerical algorithm gives the possibility of higher precision of corrosion measurements.
Keywords:Coulostatic  Tafel slopes  Integral method  Carbon steel  Sulfuric acid solution
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《物理化学学报》浏览原始摘要信息
点击此处可从《物理化学学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号