首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of 4-aminopyridine in serum by solid-phase extraction and high-performance liquid chromatography.
Authors:A van der Horst  P N de Goede  H A van Diemen  C H Polman  H J Martens
Affiliation:Department of Pharmacy, Free University Hospital, Amsterdam, Netherlands.
Abstract:
An assay for the determination of 4-aminopyridine in serum has been developed using 3,4-diaminopyridine as internal standard and reversed-phase high-performance liquid chromatography with detection at 244 nm. A mobile phase of acetonitrile-methanol-ethanol-1% ammonium carbonate (75:10:10:5) provided excellent separation of both compounds. Samples were extracted on solid-phase columns. The linearity, precision, recovery and the limit of detection were all sufficient for the routine use of this assay in clinical studies of patients treated with 4-aminopyridine.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏