首页 | 本学科首页   官方微博 | 高级检索  
     


On-line preconcentration and determination of mercury in biological samples by flow injection vapour generation inductively coupled plasma atomic emission spectrometry
Authors:Pedro Ca?ada Rudner   José Manuel Cano Pavón   Amparo García Torres  Fuensanta Sánchez Rojas
Affiliation:(1) Department of Analytical Chemistry, Faculty of Sciences, University of Málaga, E-29071 Málaga, Spain
Abstract:An FI-ICP-AES method for the determination of trace levels of mercury in biological samples has been described, which is based on the extraction of the mercury complex with 1,5-bis (di-2-pyridyl)methylene thiocarbonohydrazide (DPTH) on-line into isobuthyl-methyl ketone (IBMK). The organic phase (containing the complex) has been mixed on-line with SnCl2 in N,N-dimethylformamide. Thus, mercury vapour can be generated directly from the organic phase and separated in a gas-liquid separation device. The detection limit for mercury is 4 ng/ml and the calibration curve is linear at least from 10 to 2500 ng/ml. The relative standard deviation for 10 replicate measurements is ±1% for 100 ng/ml of Hg(II). Results from the analysis of some certified biological reference materials are given.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号