首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Manganese Dioxide Graphite Composite Electrodes Formed via a Low Temperature Method: Detection of Hydrogen Peroxide,Ascorbic Acid and Nitrite
Authors:Biljana Šljukić  Richard G Compton
Institution:Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford, OX1 3QZ, UK
Abstract:Manganese dioxide modified carbon powder was prepared via a wet impregnation method from the solution of permanganate salt. After heating at 120 °C over night in air, the formation of manganese oxide was confirmed by cathodic stripping voltammetry. The synthesized material was used for fabrication of composite electrodes and their potential application in the field of electroanalysis investigated. The composite electrodes based on the manganese dioxide modified carbon powder proved to be useful as electrodes for detection of hydrogen peroxide, ascorbic acid and nitrite ions.
Keywords:Manganese dioxide  Graphite powder  Wet impregnation procedure  Hydrogen peroxide  Ascorbic acid  Nitrite ions