测量单模波导参数的新方法:导模和漏模的双偏振测量
引用本文:金锋,李丽娜. 测量单模波导参数的新方法:导模和漏模的双偏振测量[J]. 光学学报, 1988, 0(12)
作者姓名:金锋  李丽娜
作者单位:中国科学院长春物理所(金锋),中国科学院长春物理所(李丽娜)
摘    要:本文提出测量单模波导参数的新方法.用棱镜耦合器测量两种偏振基导模和基漏模的模折射率,并由相应的四个模方程确定单模波导参数.其测量精度优于纯导模测量.用这种方法测量了单模玻璃波导参数,并对误差来源作了理论分析.

关 键 词:棱镜耦合器  单模波导参数  导模和漏模

A new method for measuring single-mode waveguide parameters: Two polarization measurements of guided and leaky modes
JIN FENG AND LI LINA. A new method for measuring single-mode waveguide parameters: Two polarization measurements of guided and leaky modes[J]. Acta Optica Sinica, 1988, 0(12)
Authors:JIN FENG AND LI LINA
Abstract:A new method for measuring single-mode wayeguide parameters is presented in this paper. Mode refractive indices of fundamental guided and leaky modes at two polarization states are measured lay the prism coupler, and single-mode waveguide parameters are determined from four corresponding mode equations. Its measuring accuracy is higher than that of measurements of pure guided modes. Single-mode glass waveguide parameters were measured toy this method, and its error sources were analysed theoretically.
Keywords:prism coupler  single-mode waveguide parameters  guided and leaky-mode.  
本文献已被 CNKI 等数据库收录!