首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Calculation of critical regimes in the ejectors with converging chamber
Authors:A V Sobolev
Institution:1. Khristianovich Institute of Theoretical and Applied Mechanics SB RAS, Novosibirsk, Russia
Abstract:The calculation procedure of the ejector with water-vapor condensation in primary nozzle and in converging chamber is presented. Calculations are performed in a wide range of temperatures of primary and secondary gases. The differences are identified in the properties of gas- and vapor-driven ejectors. Limiting mass rates ratios of gas ejectors are reached by primary temperature increase, but the highest performance of vapor-driven ejectors is realized with the use of saturated vapor.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号