首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Selective Electrochemical Analysis of Various Metal Ions at an EDTA Bonded Conducting Polymer Modified Electrode
Authors:Md Aminur Rahman  Deog Su Park  Mi-Sook Won  Su-Moon Park  Yoon-Bo Shim
Institution:1. Department of Chemistry, Pusan National University, Kumjeong-ku, Pusan 609-735, South Korea;2. Korea Basic Science Institute, Kumjeong-ku, Pusan 609-735, South Korea;3. Department of Chemistry, Pohang University, Pohang 790-784, South Korea
Abstract:An EDTA‐bonded conducting polymer modified electrode was prepared and characterized by FT‐IR. The modified electrode was used for the selective electrochemical analysis of various trace metal ions such as, Cu(II), Hg(II), Pb(II), Co(II), Ni(II), Fe(II), Cd(II), and Zn(II) at the different pHs by linear sweep and square wave voltammetry. Dynamic ranges were obtained using square wave voltammetry from 0.1 μM to 10.0 μM for Co(II), Ni(II), Cd(II), Fe(II), and Zn(II) and 0.5 nM to 20 nM for Cu(II), Hg(II), and Pb(II) after 10 min of preconcentration. The detection limits were determined to be 0.1 nM, 0.3 nM, 0.4 nM, 50.0 nM, 60.0 nM, 65.0 nM, 80.0 nM, and 90.0 nM for Cu(II), Hg(II), Pb(II), Co(II), Ni(II), Cd(II), Fe(II), and Zn(II), respectively. The technique offers an excellent way for the selective trace determination of various heavy metal ions in a solution.
Keywords:Stripping analysis  Heavy metal ion detection  Conducting polymer  EDTA modified electrode