Direct contact heat transfer between two immiscible liquids flowing in a horizontal concentric annulus
Authors:M K Shahidi  T A zbelge
Institution:

Department of Chemical Engineering, Middle East Technical University, Ankara 06531, Turkey

Abstract:Direct contact heat transfer between water and a heat transfer oil was investigated under non-boiling conditions in co-current turbulent flow through a horizontal concentric annulus. The ratio of the inner pipe diameter to the outer pipe diameter (aspect ratio) κ = 0.730?0.816; total liquid velocity (mixture velocity) VT = 0.42?1.1 m/s; inlet oil temperature Toi = 38?94°C; oil volume fraction in the flowing mixture φo = 0.25?0.75 were varied and their effects on the overall volumetric heat transfer coefficient Uv were determined at constant interfacial tension of 48 dynes/cm.

It was found that, in each concentric pipe set, the overall volumetric heat transfer coefficient increased with increasing dispersed phase volume fraction at each constant mixture velocity and reached a maximum at around φo = φw ≈ 0.5. The maximum Uv values increased with increasing total liquid velocity and decreasing aspect ratio of the annulus. The volumetric heat transfer coefficient was also found to increase with increasing inlet oil temperature and increasing total liquid velocity but to decrease with length along the test section keeping all other parameters constant. Empirical expressions for the volumetric heat transfer coefficient were obtained within the ranges of the experimental parameters.

Keywords:concentric annulus  immiscible liquids  turbulent flow  direct contact heat transfer
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号