首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Estimation of measurement uncertainty for the determination of aflatoxin M1 in milk using immunoaffinity clean-up procedures
Authors:Giovanni Calaresu  Patrizia Piras  Gavina Carta  Roberta Galarini  Giannina Chessa
Institution:(1) Istituto Zooprofilattico Sperimentale della Sardegna, Via Duca degli Abruzzi, 8-07100 Sassari, Italy;(2) Istituto Zooprofilattico Sperimentale dell’Umbria e delle Marche, Perugia, Italy
Abstract:A measurement uncertainty estimated for aflatoxin M1 determination in milk sample has been calculated using data generated from analytical method validation studies. The protocol adopted is described in detail in document LGC/VAM/1998/088. The uncertainty budget was based on precision, trueness and ruggedness data. The individual contributions are described in detail. The expanded uncertainty for aflatoxin M 1 at a concentration of 20 ng L−1 was estimated as 2.81 ng L−1. This was calculated using a coverage factor of two which gives a level of confidence of approximately 95%. Presented at AOAC Europe / Eurachem Symposium March 2005, Brussels, Belgium
Keywords:Aflatoxin M1  Uncertainty  Precision  Trueness  Ruggedness
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏