Magnetic field mapping in NMR imaging |
| |
Authors: | M R Willcott G L Mee J P Chesick |
| |
Institution: | NMR Imaging, Inc., Houston, Texas 77092. |
| |
Abstract: | The Hahn spin preparation sequence provides a practical means for rapid and sensitive mapping of magnetic field inhomogeneity in NMR imaging applications. Choice of the rf pulse delay times tau 1 and tau 2 as well as conditions and limitations on the proposed use of this sequence for chemical shift imaging are discussed. |
| |