用共振线强度比作激光等离子体诊断
引用本文:沈百飞 张杰. 用共振线强度比作激光等离子体诊断[J]. 光学学报, 1995, 15(6): 12-714
作者姓名:沈百飞 张杰
作者单位:中国科学院上海光学精密机械研究所
摘    要:用流体和原子物理模型,计算了类Li、类Be离子共振线强度比随功率密度的变化,并讨论了共振线强度比和实现复合机制X射线激光所需的初始条件之间的联系。同时共振线强度比还可用于激光等离子体的诊断。

关 键 词:X射线激光 激光 等离子体诊断 共振线强度比
收稿时间:1994-05-10

Diagnoses of Laser-Produced Plasma with Intensity ratio of Resonance Lines
Shen Baifei, Zhang Jie, Han Shensheng,Zhang Zhengqua, Xu Zhizhan. Diagnoses of Laser-Produced Plasma with Intensity ratio of Resonance Lines[J]. Acta Optica Sinica, 1995, 15(6): 12-714
Authors:Shen Baifei   Zhang Jie   Han Shensheng  Zhang Zhengqua   Xu Zhizhan
Abstract:The pumping intensity yaring ration of intensities of resonance lines of Li-like and Be-like ions in laser irradiated slab target is calculated by using hydrodnamic and atomic codes. Correspondence between the ratio and requirement for gain of Li-like ions is analysed. A useful diagnistic method is also proposed for laserwproduced plasma using the intensity ratios.
Keywords:plasma diagnoses   X-ray laser   Li-like ions.  