Liquid chromatographic analysis of mexiletine in serum, with alternate application to tocainide, procainamide, and N-acetylprocainamide. |
| |
Authors: | E vasBinder T Annesley |
| |
Affiliation: | Department of Pathology, University Hospital, Ann Arbor, MI 48109-0054. |
| |
Abstract: | A simple and precise high performance liquid chromatographic method for the determination of mexiletine in human serum or plasma is described. Following addition of N-propionylprocainamide as internal standard the specimens are extracted, under basic conditions, into methylene chloride. After removal of the aqueous layer the drug is back-extracted into dilute acid, which is then injected directly for analysis. The extraction efficiency is 79% for both mexiletine and internal standard, and the assay is linear to 4 mg/L (twice upper therapeutic concentration). Inter-run coefficients of variation are 3.0% or less. The relative retention time of mexiletine to internal standard averages 1.3. An adaptation of this method is described for an alternate application to the analysis of tocainide, procainamide and N-acetylprocainamide. |
| |
Keywords: | |
|
|