首页 | 本学科首页   官方微博 | 高级检索  
     检索      


CE Determination of 2-(9-Carbazole)ethyl Chloroformate-Labeled Oligopeptides
Authors:Chenxu Ding  Xuejun Sun  Xianen Zhao  Wenchen Zhao  Yulin Li  Honglun Wang  Yourui Suo  Jinmao You
Institution:(1) Northwest Plateau Institute of Biology, Chinese Academy of Sciences, Xining Qinghai, 810001, People’s Republic of China;(2) College of Chemistry Science, Qufu Normal University, Qufu Shandong, 273165, People’s Republic of China;(3) Department of Pharmacy, Qinghai Nationalities Institute, Xining Qinghai, 810007, People’s Republic of China;(4) Graduate School of the Chinese Academy of Sciences, Beijing, 100039, People’s Republic of China
Abstract:A pre-column derivatization method for sensitive determination of oligopeptides, using the tagging reagent 2-(9-carbazole)ethyl chloroformate (CEOC-Cl) followed by capillary electrophoresis (CE) with diode-array detection, has been developed. Maximum yield close to 100% were observed when a three to fourfold molar excess of reagent was used at pH 9.0–10.0. Excess reagent was extracted with n-hexane–ethyl acetate 9:1–10:1 (v/v); this enabled direct analysis using CE with no significant disturbance from the major fluorescent reagent degradation by-products. The effects on the results of buffer pH and of SDS and organic modifier concentrations were examined. Good baseline resolution in the separation of five CEOC-peptides was achieved with a 48.5-cm total length (effective length 40 cm) 50-μm inner diameter capillary column.
Keywords:Capillary electrophoresis  2-(9-Carbazole)ethyl chloroformate (CEOC-Cl)  Oligopeptides  Derivatization