首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Low-coherent light-source angular interferometer using a square prism and the angular-scanning technique
Authors:Lin Shyh-Tsong  Yeh Sheng-Lih  Chang Chien-Wei
Institution:Department of Electro-optical Engineering, National Taipei University of Technology, 1, Section 3, Taipei, Taiwan. f10402@ntut.edu.tw
Abstract:An interferometer based on using low-coherent light source, a square prism, and the angular-scanning technique is proposed for absolute angular-displacement determinations. An angular displacement of the square prism shifts the correlogram, which is modulated by an envelope function, of the interference signal of the beams passing through the prism. This angle can thus be discovered by detecting the shifting of the envelope peak. A setup constructed to validate the interferometer is used. The results of using this setup are then presented.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号