A comparison between ultrasonic array beamforming and super resolution imaging algorithms for non-destructive evaluation |
| |
Authors: | Chengguang Fan Mihai Caleap Mengchun Pan Bruce W. Drinkwater |
| |
Affiliation: | 1. College of Mechatronic Engineering and Automation, National University of Defense Technology, Changsha 410073, PR China;2. Department of Mechanical Engineering, University of Bristol, Queen’s Building, University Walk, Bristol BS8 1TR, UK |
| |
Abstract: | In this paper the total focusing method, the so called gold standard in classical beamforming, is compared with the widely used time-reversal MUSIC super resolution technique in terms of its ability to resolve closely spaced scatterers in a solid. The algorithms are tested with simulated and experimental array data, each containing different noise levels. The performance of the algorithms is evaluated in terms of lateral resolution and sensitivity to noise. It is shown that for the weak noise situation (SNR > 20 dB), time-reversal MUSIC provides significantly enhanced lateral resolution when compared to the total focusing method, breaking the diffraction limit. However, for higher noise levels, the total focusing method is shown to be robust, whilst the performance of time-reversal MUSIC is degraded. The influence of multiple scattering on the imaging algorithms is also investigated and shown to be small. |
| |
Keywords: | Ultrasonic array Modelling Post processing Lateral resolution Noise |
本文献已被 ScienceDirect 等数据库收录! |
|