首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Vacuum Arc Plasma Centrfuge for Element and Isotope Separation
Abstract:Vacuum arcs have been studied extensively in the past several decades with applications primarily in the areas of switching, vacuum remelting, and vapor deposition. Application of the vacuum arc for element and isotope separation has been studied recently and is reviewed in this paper. An arc was produced in a 30-cm-diameter 4-m-long cylindrical chamber with coaxially mounted electromagnets providing a 2.6-m-long constant axial magnetic field of up to 6 kG. The vacuum discharge between a solid cathode and a mesh anode was triggered electrically. A pulse-forming network (PFN) of 70-m? impedance provided nearly constant-current discharge pulses of several kiloamps and 6-12-ms duration. The magnetized plasma column, flowing axially from the anode with a typical velocity of 106 cm/s, rotated nearly as a solid body. This rotation was due to the E × B drift, produced by the axial magnetic field and the radial electric field across the column. A typical rotation frequency was 105 rad/s. The centrifugal effect due to the rotation caused a radial redistribution of ions within the plasma column, thereby producing elemental and isotope enrichment. The separation was observed to increase exponentially with the square of the radius. Enrichments of up to 300 percent were measured in a Cu-Zn plasma. The radial plasma density profile was found to be roughly Gaussian, with central electron densities of about 1013 cm-3. The radial potential profile across the column was measured and found to be parabolic with radius.