首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Effects of oxidation and surface roughness on contact angle
Authors:Kwang Taek Hong

Harris Imadojemu

R L Webb

Institution:

Mechanical Engineering Department, USA

School of Science, Engineering, USA

Mechanical Engineering Department Penn State University, University Park, Pennsylvania 16802, USA

Abstract:Contact angle is known to be a parameter that effects boiling. This study was undertaken to measure contact angle of high and low surface tension fluids on copper and aluminum surfaces.Data were taken for polished, oxidized, and rough surfaces. A simple, yet fairly accurate method of measuring the static equilibrium contact angle of a solid/liquid interface is presented. The principles of a line light source and tilting plate were modified and then combined in the design of this apparatus. The angles obtained and their variation with the solid surface properties were in good agreement with previously published data. The contact angle of distilled water o of the organic fluids and refrigerants tested were in the range of 2–5°. Roughness and oxidation reduce the contact angle. If the depth of the roughness is less than 0.5 μm contact angle. The apparatus is fairly simple in construction, is inexpensive, and has good reproductibity. The measured angles were then compared to those measured with the sessile drop method.
Keywords:contact angles  sessile drop  tilting plate  wettability  surface roughness  surface tension
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号