首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Trace element determination in seawater by ICP-SFMS coupled with a microflow nebulization/desolvation system
Authors:Turetta  Clara  Cozzi  Giulio  Barbante  Carlo  Capodaglio  Gabriele  Cescon  Paolo
Institution:(1) Institute for the Dynamics of Environmental Processes, CNR, Dorsoduro 2137, 30123 Venice, Italy;(2) Department of Environmental Sciences, University Calsquo Foscari Venice, Dorsoduro 2137, 30123 Venice, Italy
Abstract:Direct and simultaneous determination of Al, Ag, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Pb, Sb, U, V and Zn in diluted (1:10 v:v) seawater from the Antarctic Ocean and the Venice Lagoon at the ng mL–1 and pg mL–1 level has been performed by using an inductively coupled plasma sector field mass spectrometer (ICP-SFMS). Samples were analysed by using a PFA microflow nebulizer coupled with a desolvation system or a PFA microflow nebulizer coupled with a Teflon spray chamber, respectively. Measurements were carried out at low (LR, m/Deltam=300), medium (MR, m/Deltam=3,000) and high (HR, m/Deltam=7,500) resolutions depending on the studied isotope. To avoid contamination, sample pre-treatment was carried out in a clean laboratory equipped with a Class 100 vertical laminar flow hood. Concentration ranges (minimum–maximum in ng mL–1) found in the Antarctic seawater samples (in depth profiles) were: Ag 0.0004–0.0018, As 0.69–1.32, Cd 0.031–0.096, Co 0.018–0.065, Cr 0.18–0.46, Cu 0.04–1.58, Fe 0.13–1.63, Mn 0.02–0.12, Mo 5.97–12.46, Pb 0.007–0.074, Sb 0.033–0.088, U 0.5–1.9, V 0.6–2.5 and Zn 0.16–0.80. Concentration ranges (min–max in ng mL–1) found in the Venice Lagoon water samples (temporal profile from a benthic chamber experiment) were: Al 0.24–0.61, Ag 0.007–0.031, As 1.42–2.27, Cd 0.050–0.182, Co 0.440–1.461, Cr 0.15–0.34, Cu 0.81–2.46, Fe 0.25–1.66, Mn 11.6–31.7, Mo 6.50–10.6, Pb 0.047–0.225, Sb 0.240–0.492, U 1.7–3.3, V 1.3–2.8 and Zn 5.20–21.5. The detection limits range between 0.06 pg mL–1 for Ag and U to 15 pg mL–1 for Fe. In order to check the accuracy of the analytical procedure, measurements of the trace elements in a certified reference material (coastal Atlantic seawater, CASS-4-NRCC) were compared with the certified values. In addition, the results from the Antarctic and Venice Lagoon samples were compared with those obtained by using different analytical techniques.
Keywords:Trace elements  Seawater  ICP-SFMS  Desolvation system
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号