首页 | 本学科首页   官方微博 | 高级检索  
     检索      

强流ECR离子源引出系统研究
引用本文:王云,陈志,赵红卫,赵阳阳,孙良亭,杨尧,钱程,武启,马鸿义,张文慧,张子民,张雪珍,刘占稳.强流ECR离子源引出系统研究[J].原子核物理评论,2013,30(2):141-146.
作者姓名:王云  陈志  赵红卫  赵阳阳  孙良亭  杨尧  钱程  武启  马鸿义  张文慧  张子民  张雪珍  刘占稳
作者单位:中国科学技术大学核科学技术学院,安徽 合肥 230027;
摘    要:为了提高强流ECR 离子源的引出束流品质,分别设计了1# 和2# 引出系统,利用束流引出模拟软件PBGUNS 对1# 和2# 引出系统进行了质子束流引出与传输的模拟计算,结合实际测得的发射度数据分析引出系统,发现2# 引出系统比1# 引出系统引出束流品质高。对ECR 离子源引出系统的电势等位线分布等参数引起的球差进行了简单数学推导及MATLAB 绘图,并结合1# 和2# 引出系统束流相图模拟结果证明了球差会使引出束流品质有效发射度增长,通过适当加大电极孔径可改善束流聚焦情况,得到了束流光学聚焦较好的束流引出系统设计。To improve the quality of extracted ion beam from a high current ECR ion source, 1# and 2# extraction systems were designed and tested. The PBGUNS code was used to simulate the 1# and 2# extraction systems of proton ion beam. The emittance measurement results with the two different extraction systems were compared and analyzed with the simulation, the conclusion that more high quality beam extracted from 2# system than 1# system was got. The formula derivation of ECR ion source extraction system spherical aberration and MATLAB drawing was done by the analyzing on the distribution of extraction field equipotentials, effective emittance increasing caused by spherical berration was proved by 1# and 2# extraction systems beam phase space simulation result, beam focusing would be improved if electrode hole size increasing appropriately and a general concept on good optics focusing of ion beam extraction system was proposed finally.

关 键 词:ECR    束流引出系统    电势等位线分布    球差
收稿时间:1900-01-01

Study on Extraction System for High Current ECR Ion Source
WANG Yun,CHEN Zhi,ZHAO Hongwei,ZHAO Yangyang,SUN Liangting,YANG Yao,QIAN Cheng,WU Qi,MA Hongyi,ZHANG Wenhui,ZHANG Zimin,ZHANG Xuezhen,LIU Zhanwen.Study on Extraction System for High Current ECR Ion Source[J].Nuclear Physics Review,2013,30(2):141-146.
Authors:WANG Yun  CHEN Zhi  ZHAO Hongwei  ZHAO Yangyang  SUN Liangting  YANG Yao  QIAN Cheng  WU Qi  MA Hongyi  ZHANG Wenhui  ZHANG Zimin  ZHANG Xuezhen  LIU Zhanwen
Institution:School of Nuclear Science and Technology, University of Sciences and Technology of China, Hefei 230027, China;University of Chinese Academy of Sciences, Beijing 100049, China;
Abstract:To improve the quality of extracted ion beam from a high current ECR ion source, 1# and 2# extraction systems were designed and tested. The PBGUNS code was used to simulate the 1# and 2# extraction systems of proton ion beam. The emittance measurement results with the two different extraction systems were compared and analyzed with the simulation, the conclusion that more high quality beam extracted from 2# system than 1# system was got. The formula derivation of ECR ion source extraction system spherical aberration and MATLAB drawing was done by the analyzing on the distribution of extraction field equipotentials, effective emittance increasing caused by spherical berration was proved by 1# and 2# extraction systems beam phase space simulation result, beam focusing would be improved if electrode hole size increasing appropriately and a general concept on good optics focusing of ion beam extraction system was proposed finally.
Keywords:
点击此处可从《原子核物理评论》浏览原始摘要信息
点击此处可从《原子核物理评论》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号