Improvement of plant parameters of the ROBO gamma irradiation facility due to design modification
Authors:A Kovacs A Moussa  I Othman C Del Valle Odar  A Seminario  M Linares  P Huamanlazo  J Aymar  R Chu
Institution:

Institute of Isotopes of the Hungarian Academy of Sciences, H-1525, Budapest, P.O.B. 77., Hungary

Syrian Atomic Energy Commission, Damascus, P.O.B. 6091, Syria

IPEN & Inmune S.A., Lima, Peru

MDS Nordion, P.O.B. 13500, Kanata, Ontario, K2K 1X8, Canada

Abstract:Two industrial scale, “ROBO” type 60Co gamma irradiation facilities have recently been put into operation in Syria and Peru, and the dosimetry commissioning of both plants have been carried out to determine dose distribution within products and to calculate plant parameters such as efficiency, dose uniformity ratio and throughput. There are some design modifications between the two plants in connection with the location of the carriers with respect to the source plaque and also to each other. The effect of these construction modifications on the plant parameters is discussed in the analysis of the dose distribution data measured in the carriers with depth and height among the four irradiation rows on both sides of the source plaque. The plant parameters were also calculated for different product densities using the technical data of the facilities, and the calculated and measured results were compared to each other.
Keywords:Author Keywords: Radiation processing  gamma irradiation facility  dosimetry commissioning  operation parameters