首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Tablet disintegration monitored by magnetic resonance imaging
Authors:S Kwieciński  M Weychert  A Jasiński  P Kulinowski  I Wawer  E Sieradzki
Institution:1. MRI Laboratory, Institute of Nuclear Physics, Radzikowskiego 152, 31-342, Kraków, Poland
2. Faculty of Pharmacy, The Medical University of Warsaw, Warsaw, Poland
Abstract:The disintegration of bromhexin tablets was monitored by magnetic resonance imaging. The fast imaging method FLASH with spoiling gradients was used to obtain images of the tablets in short time intervals. The rate of the disintegration depends on the preparation method, kind and percentage of the carrier (polyethylene glycol, lactose). Solid dispersion with slow evaporation of solvent yields materials with decreased dissolution rate. Increasing molecular mass of polyethylene glycol and its percentage content also hampers disintegration.
Keywords:
本文献已被 SpringerLink 等数据库收录!